Asset & Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7
HomeHome > Products > Busbar > Asset & Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7
Asset & Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

Asset & Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

BBIC-Bus Bar Insulation Connection Cover up to 40.5kV Bus bar insulation connection cover "UE-BBIC", A wide range of pre
Basic Info
Model NO. UE-BBIC-T7
HS Code 8547200000
Production Capacity 1000000PCS/Year
Product Description

BBIC-Bus Bar Insulation Connection Cover up to 40.5kV
Bus bar insulation connection cover "UE-BBIC", A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in terms ofdamage to equipment, reduced reliability. Most of event of this nature can be prevented by covering the strategicallyvulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devicesthat are factory-engineered to meet applicable switchgear performance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

 

Selection guide
Rated voltage0.6/1(1.2)kV12~24 kV36-42 kV
Wall thickness1mm1.5-2mm2.5-3.2mm

Material property
Property Test method Typical data
Tensile strength GB/T 1040≥5MPa
Elongation at break GB/T 1040≥200%
Dielectric strength GB/T 1408.1≥12kV/mm (2mm)
Volume resistance GB/T 1410 ≥1012Ω.cm
Water awbsorptionGB/T 1034<1%

Production

Applications

Asset &amp; Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

Asset &amp; Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

Asset &amp; Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

Asset &amp; Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7

Asset &amp; Wildlife Protection Cover/Switchgear Bus bar Insulation Cover/busbar connection insualting cover/Insulation Enhancement cover/UE-BBIC-T7